HP Hardware (HPH1)
Description
This probes monitors the status of HP hardware
Release notes
Version 1.0.0 - Early deployment
- Feature: Initial release (M12556)
- Dependency:
- SNMP Agent module >= 3.8.0
- Monitoring Service module >= 2.0.1 installed on the BMS
Resource configuration interface
Compatibility
This resource has been validated the following hardware:
- HP DL120 G6
- HP DL120 G7
- HP DL320 G8
- HP DL360 G7
- HP DL360 G8
Other HP hardware may be compatible but cannot be guaranteed.
Resource parameters
This probe generates graphs with the following metrics if the sensors are available on the hardware:
- Fan speed
- Ambient temperature
- CPU temperature
- Memory temperature
- Powersupply temperature
- System temperature
- Storage temperature
- Other temperatures: any sensors that don't belong in the categories above.
Alarms
This probe can report following alarm states:
- CRITICAL:
- One of the redundant power supplies (if available) has failed.
- Temperature threshold of a sensor set by the manufacturer is exceeded
- One of the fans has failed
- UNKNOWN: the test could not be performed.
Possible causes
An exceeded temperature threshold may be caused by:
- a broken fan
- obstructed air outlet
- air conditioning failure in the datacenter
A power supply alert may be caused by:
- a faulty powersupply
- a poorly connected or disconnected power cable
- power failure in one of the power circuits